Evaluasi performa struktur bangunan eksisting terhadap beban gempa Zona 1 dan Zona 2 di Kabupaten Kotawaringin Timur
DOI:
https://doi.org/10.37253/leader.v4i1.12035Keywords:
Seismic load; Seismic zone; Structural performance; Existing buildings; SAP2000; SNI 1726:2019Abstract
Based on the seismic hazard map of SNI 1726:2019, East Kotawaringin Regency is classified as a Zone-1 region with relatively very low seismic potential. However, an earthquake with a magnitude of approximately 4.5 occurred on 30 October 2023, indicating the possible need to reassess the regional seismic hazard classification from Zone-1 to Zone-2. This study aims to evaluate the structural performance of existing buildings under seismic loads corresponding to Zone-1 and Zone-2 conditions in accordance with SNI 1726:2019. The analysis results indicate that the total dynamic base shear of all buildings exceeds 85% of the total static base shear, satisfying the seismic design requirements. Interstorey drift evaluation shows that all buildings meet the allowable limits under Zone-1 seismic loading, whereas under Zone-2 loading, one building does not satisfy the drift requirement, representing 6.66% of the total buildings analyzed. The mass participation ratios in the principal seismic directions exceed 90%, confirming that the number of vibration modes considered is sufficient to represent the dynamic behavior of the structures. The increase in seismic demand from Zone-1 to Zone-2 results in a relatively small increase in axial forces in columns of 0.93%, while significant increases are observed in shear forces and bending moments, with column shear forces increasing by 12.48% in the x-direction and 11.24% in the y-direction, and bending moments increasing by 12.98% in the x-direction and 11.09% in the y-direction. For beam elements, shear forces increase by 3.82% and bending moments by 4.87%. The structural performance evaluation shows that the average ratio of nominal capacity to ultimate demand increases from 0.65 under Zone-1 conditions to 0.70 under Zone-2 conditions, corresponding to an increase of 8.49%. Furthermore, three buildings are classified as unsafe, accounting for 20% of the total buildings evaluated.
Downloads
References
Badan Standardisasi Nasional. (2019). SNI 2847:2019—Persyaratan beton struktural untuk bangunan gedung dan penjelasan. Jakarta: BSN.
Badan Standardisasi Nasional. (2019). SNI 1726:2019—Tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan non-gedung. Jakarta: Badan Standardisasi Nasional.
Ekatama, Y., Nur, K. S., & Gani, M. (2023). Analisis Gaya Geser Dasar dan Simpangan Struktur Gedung Utama Fakultas Teknik Universitas Negeri Gorontalo Berdasarkan SNI. Jurnal Sains dan Teknologi Tadulako, 9(1), 45-58.
Handayani, N., Atmajaya, P., & Silaban, R. S. (2025). Evaluasi Desain Struktur Gedung Pengadilan Agama Sendawar Terhadap Beban Gempa. AGREGAT, 10(1), 1326-1331.
Irsyam, M., Cummins, P. R., Asrurifak, M., Faizal, L., Natawidjaja, D. H., Widiyantoro, S., ... & Syahbana, A. J. (2020). Development of the 2017 national seismic hazard maps of Indonesia. Earthquake Spectra, 36(1_suppl), 112-136.
Morib, M. A., Telaumbanua, H. Y., & Gulo, F. (2024). Pengaruh Peningkatan Percepatan Gempa Periode Pendek (SS) Terhadap Struktur Bertingkat di Daerah Istimewa Yogyakarta. JURNAL TEKNIK SIPIL UKRIM, 1(1), 8-17.
Nugroho, N. S. (2022). Evaluasi Kekuatan Struktur Bangunan Bertingkat Berdasarkan Respon Spektrum Percepatan Gempa SNI 03-1726-2019 (Doctoral dissertation, IPB University).
Rahayu, T., Nasution, Z., Roesyanto, & Karnawati, D. (2022). Regional zonation based on seismic vulnerability using local site effect analysis and potential damage to the city of Medan (North Sumatra, Indonesia) due to earthquake. Geoenvironmental Disasters, 9(1), 26.
Yuviano, A. S. Y., Sarasanty, D., & Asmorowati, E. T. (2025). ANALISA RESPON SPEKTRUM TERHADAP STRUKTUR GEDUNG SEKOLAH MENGGUNAKAN SAP200. Elemen: Jurnal Teknik Sipil, 7(1).